| Remote Condenser – Air Cooled Industrial Refrigeration Process Cooling Split Modules |
| 
| | |
|
|

| These chiller modules are used when the air inside the plant is either corrosive, extremely dusty, hot, where supplemental heating is of no benefit, or where the plant is air conditioned. These modules consist of an inside chiller unit and an air cooled condenser for remote mounting. Electrical- 460 / 575 / 230 / 380 Volts 60 / 50 Hz
- 120 Volt Single Phase Control Voltage
- Microprocessor Controller
- Operating and Fail Lights
- UL or CSA Approved Components
|
|
Because of the simple hookup required on BERG packaged chillers, customers usually have them running the same day as delivery. |
|
Highlights - Compressor (HP) 20 - 120 or More!
- Cooling Capacity ( Refrigeration tons ) 15 to 300 or More!
- Heating (BTU/hr) 270k - 846k
( Multi-Cylinder, Semi Hermetic Compressor ASR ) - Forced feed oil lubrication system Discharge and suction service valves
- Spring mounted to chiller main frame
- Suction, gas-cooled motor
( Multi-Cylinder, Direct Drive Compressor AOR ) - Forced feed oil lubrication system
- Discharge service valve
- Solid mounted to chiller main frame
- NEMA approved open drip-proof motor
( Screw Compressor AZR ) - Discharge and suction service valves
- Solid mounted to chiller main frame
Frame - Frame Manufactured from heavy gauge structured steel tube with welded construction.
| 
|
|

| Chiller Vessel - High efficiency shell and tube construction
- Coded vessel Steel shell on water side
- Copper tube with inner fin on refrigerant side
Tested under load conditions prior to shipment All safety controls are factory set and checked Safety Controls - Freeze-up controls
- High and low refrigerant pressure controls
- Compressor motor overload protection
- Oil pressure safety control
- Refrigerant pressure relief valve
|
|
|
Central Control Electrical Panel A custom electrical control panel allows one point hookup and may include; - HMI ( Human Interface Device ) touchscreens
- PLC ( Programable Logic Control )
- SCADA ( Supervisory Control And Data Acquisition ) Communication Systems
- 24/7 alarm reporting to beepers or cell phones
All pump starters, fuses, disconnect, control voltage transformer, run and fail lights, are housed in a common NEMA RATED panel. | 
|
|
|
|

| Air Cooled Outdoor or Indoor Remote Condenser or Blower - Heavy construction while maintaining maximum heat transfer
- Seamless copper tubing
- Aluminum fins
- Permanent metal-to-metal contact
- Dynamically balanced centrifugal blowers
- Blowers are belt-driven by an open, drip proof motor
|
|
|

|
|

|
| |
| |
BERG Chilling Systems Inc. - Toronto Ontario Canada Industrial Refrigeration / Commercial Refrigeration / Process Pumps / Process Cooling Systems / HVAC Systems / Cooling Towers Tel: +01 (416) 755-2221 Fax: +01 (416) 755-3874 Email: bergsales@berg-group.com |
|