The New BERG SC7 Controller

We are pleased to present our latest generation of microprocessor controllers - The SC7, a new controller that provides standard features that were only available as options on our earlier controllers.

Highlights:

The SC7 comes loaded with prewritten programs for all your chiller applications, and includes enough flexibility to add additional features for very specialized applications.

The SC7 provides complete monitoring of your chiller’s performance and operation. It monitors the process water temperature, and controls the set point temperature by lead/lagging (staging) and loading and unloading the compressors. The SC7 controls and unloads the compressor operation efficiently in proportion to changes in cooling load, and your typical temperature accuracy can be maintained at +/-1°F.

To ensure optimal efficiency and help Maintenance Technicians service the chiller, the Berg SC7 monitors and displays refrigerant discharge and suction pressure for each compressor as well as evaporator inlet and outlet temperatures. In addition, here is a partial list of the many features of the Berg SC7:

 

Standard Control Features:
  • Refrigerant Discharge and Suction pressure display for each compressor
  • Temp in /out of evaporator(s) and temperature to process C/F display
  • Crankcase heater operation monitoring to protect the compressor
  • Compressor run time display Maintenance alarms for run time and evaporator performance
  • Status display of all inputs for easy system trouble shooting
  • Monitoring of all safety inputs for compressor and system operating.
  • Alarm events are shown in text display Audible and visual alarm on controller display with silence
  • Temperature and Pressure sensor failure alarms
  • High system temperature alarm with adjustable time delay for system pull down
  • Temperature and Pressure on screen calibration (Password protected)
  • Field adjustable operating parameters (Password protected)
  • Auto compressor unloading for high Discharge pressure during pull down to avoid compressor overloading
  • Unloaded compressor starting
  • Automatic lead/lag compressor change and compressor
  • Anti cycle System alarm help pages Single switch on off operation for easy day to day operation
  • Five hour power up delay after a power failure to protect the compressor
SC7 Medium User Interface

 (Interface used with chillers with one or two compressors)

  • 4 x 20 character LCD backlit display
  • 6 Navigation keys
  • LCD Function lights
  • 10 Event alarm history
SC7 Master display (Optional)

 (Interface used with chillers with three or more compressors)

  • Large 4.5” x 2.5” multi line & icon display screen
  • 9 Navigation keys
  • LCD Function lights
  • 10 Event alarm history (with time stamping)
  • Temperature, Pressure and set point on screen trending graph
SC7 Optional Features
  • 0-10 VDC output signal for remote temperature display
  • Compressor operating current display
  • N2 open or LonWorks communication cards
  • Remote display interface
  • Remote alarm beacon
<<< Return to Previous Page
We have Extensive Resources in the fields of Refrigeration Engineering Service and Refrigeration Consulting Service.This web page provides an Overview of BERG Engineering Specialties. BERG Customer Service Page  BERG Online Quoting Systems  A Detailed Table of Contents Legend for this Website

BERG Chilling Systems Inc. - Toronto Ontario Canada
Industrial Refrigeration / Commercial Refrigeration / Process Pumps / Process Cooling Systems / HVAC Systems / Cooling Towers
Tel: +01 (416) 755-2221 Fax: +01 (416) 755-3874 Email: bergsales@berg-group.com