Indoor
Refrigeration Units - Heat Recyclers
Air Cooled Chiller Modules ( ACS )
|

|
|
|
|

|
BERG air-cooled
modules are designed for applications where it is desirable to convert the heat
from molds, rolls, etc. into hot air to heat the plant. These units, called
"HEAT RECYCLERS", provide supplemental heating for the plant in the winter and
ventilation during summer. This is achieved by changing the damper settings in
the ductwork. (Sized from 20-70 tons.)
|

|
|
|
Because
of the simple hookup required on BERG packaged chillers, customers usually have
them running the same day as delivery.
|
|
Highlights
-
Compressor (HP) 20 - 120 or More!
-
Cooling Capacity ( Refrigeration tons ) 15 to 300
or More!
-
Heating (BTU/hr) 270k - 846k
( Multi-Cylinder, Semi Hermetic
Compressor ACS )
-
Forced feed oil lubrication system Discharge and
suction service valves
-
Spring mounted to chiller main frame
-
Suction, gas-cooled motor
( Multi-Cylinder, Direct Drive
Compressor ACO )
-
Forced feed oil lubrication system
-
Discharge service valve
-
Solid mounted to chiller main frame
-
NEMA approved open drip-proof motor
( Screw Compressor ACZ )
-
Discharge and suction service valves
-
Solid mounted to chiller main frame
|
 |
|

|
Frame
-
Frame Manufactured from heavy gauge structured steel tube with welded
construction.
|
|
Tested
under load conditions prior to shipment
All safety controls are factory
set and checked
Safety Controls
-
Freeze-up controls
-
High and low refrigerant pressure controls
-
Compressor motor overload protection
-
Oil pressure safety control
-
Refrigerant pressure relief valve
|

|
|

|
Electrical
-
460 / 575 / 230 / 380 Volts 60 / 50 Hz
-
120 Volt Single Phase Control Voltage
-
Microprocessor Controller
-
Operating and Fail Lights
-
UL or CSA Approved Components
|
|
These
air cooled chiller modules are recommended for applications with clean air and
supplemental heat requirements.
The ACS is part of
BERG's
complete line of heat reclaim chiller modules. These are used in conjunction
with a BERG
Pump Tank Assembly to create a complete Central Chilled air cooled System.
This system
Reclaims waste energy to heat the plant during the winter months and superb
ventilation during the summer months.
BERG's
chillers incorporate high air flow to eliminate many of the problems associated
with air stratification. All components are configured on the frame for easy
maintenance and simple start-up.
|

|
|

|
Air Cooled Outdoor or
Indoor Remote Condenser or Blower
-
Heavy construction while maintaining maximum heat
transfer
-
Seamless copper tubing
-
Aluminum fins
-
Permanent metal-to-metal contact
-
Dynamically balanced centrifugal blowers
-
Blowers are belt-driven by an open, drip proof motor
|

|
|
|
Central
Control Electrical Panel
A custom electrical control
panel allows one point hookup and may include;
-
HMI ( Human Interface Device ) touchscreens
-
PLC ( Programable Logic Control )
-
SCADA ( Supervisory Control And Data Acquisition )
Communication Systems
-
24/7 alarm reporting to beepers or cell phones
All pump starters, fuses,
disconnect, control voltage transformer, run and fail lights, are housed in a
common NEMA RATED panel.
|

|
|
Central
Thermostat Control System
This system is used
to control chiller units in a multiple central chilling system.
|
|
|

|

|
|
|
|
|
|
|
|
|
BERG Chilling Systems
Inc. - Toronto Ontario Canada
Tel: +01 (416) 755-2221 Fax: +01 (416) 755-3874 Email: bergsales@berg-group.com |
|